How to Specify Max-Emitterline

How to Specify: 16MM Max-Emitterline

3/8 GPH: (1.5 LPH)

16mm 3/8 Gallon Per Hour Max-Emitters inserted into 7510 LLDPE tubing - wall thickness from .035" to .045" - internally installed Max-Emitters with 330º screens and 330º flow path. Minimum 150 Screen Openings. Two outlet holes At 180º apart and Cv = +/- 3%. Coil length is 1000' (305 Meters). Roll Dimensions = 32" Diameter x 16" I.D. x 9" High

1/2 GPH: (2 LPH)

16mm 1/2 Gallon Per Hour Max-Emitters inserted into 7510 LLDPE tubing - wall thickness from .035" to .045" - internally installed Max-Emitters with 330º screens and 330º flow path. Minimum 150 Screen Openings. Two outlet holes At 180º apart and Cv = +/- 3%. Coil length is 1000' (305 Meters). Roll Dimensions = 32" Diameter x 16" I.D. x 9" High

1 GPH: (4 LPH)

16mm 1 Gallon Per Hour Max-Emitters inserted into 7510 LLDPE tubing - wall thickness from .035" to .045" - internally installed Max-Emitters with 330º screens and 330º flow path. Minimum 150 Screen Openings. Two outlet holes At 180º apart and Cv = +/- 3%. Coil length is 1000' (305 Meters). Roll Dimensions = 32" Diameter x 16" I.D. x 9" High

2 GPH: (8 LPH)

16mm 2 Gallon Per Hour Max-Emitters inserted into 7510 LLDPE tubing - wall thickness from .035" to .045" - internally installed Max-Emitters with 330º screens and 330º flow path. Minimum 150 Screen Openings. Two outlet holes At 180º apart and Cv = +/- 3%. Coil length is 1000' (305 Meters). Roll Dimensions = 32" Diameter x 16" I.D. x 9" High

How to Specify: 20MM Max-Emitterline

1/2 GPH: (2 LPH)

20mm 1/2 Gallon Per Hour Max-Emitters inserted into 7510 LLDPE tubing - wall thickness from .035" to .045" - internally installed Max-Emitters with 330º screens and 330º flow path. Minimum 150 Screen Openings. Two outlet holes At 180º apart and Cv = +/- 3%. Coil length is 1000' (305 Meters). Roll Dimensions = 32" Diameter x 16" I.D. x 9" High

1 GPH: (4 LPH)

20mm 1 Gallon Per Hour Max-Emitters inserted into 7510 LLDPE tubing - wall thickness from .035" to .045" - internally installed Max-Emitters with 330º screens and 330º flow path. Minimum 150 Screen Openings. Two outlet holes At 180º apart and Cv = +/- 3%. Coil length is 1000' (305 Meters). Roll Dimensions = 32" Diameter x 16" I.D. x 9" High

2 GPH: (8 LPH)

20mm 2 Gallon Per Hour Max-Emitters inserted into 7510 LLDPE tubing - wall thickness from .035" to .045" - internally installed Max-Emitters with 330º screens and 330º flow path. Minimum 150 Screen Openings. Two outlet holes At 180º apart and Cv = +/- 3%. Coil length is 1000' (305 Meters). Roll Dimensions = 32" Diameter x 16" I.D. x 9" High